similar to: Anyone using gr303?

Displaying 20 results from an estimated 2000 matches similar to: "Anyone using gr303?"

2004 Jul 06
2
GR303
iH where can i find documentation on Asterisk's support for GR303??? thanks - hcir
2005 Mar 23
1
GR-303 from Central Office supported?
I'm a little confused on whether the GR303 support in * will accept calls from a Siemens central office that has GR303. Anyone know for sure?
2010 Jun 25
2
Big time system
We are an asterisk user... small time system 50-100 users or so. But, we have an opportunity to get into a big time telecom activity. It would have 2000 to 30,000 user lines per city, and we would like to have those brought back to a central location for control and because transport can be more economical than remote site rentals, maintenance and personnel. We could take the local lines into
2004 Apr 07
2
Siemens EWSD 13
Hi all, Has anyone got any experience with hooking Asterisk up with a Siemens EWSD 13 switch over a E1/PRI ? We're located in Belgium (Europe) and one of our telecom partners uses this switch. We connected one of our TE410P ports with their switch, but the status light on the TE410P card keeps blinking red. On their side they are getting a DSA (distance service alarm) error, so this
2004 Jul 19
3
Numbering Plan and Siemens EWSD
Hi all, We're trying to hook up our Asterisk config (Card: TE410P) with a Siemens EWSD switch. The link is ok on both ends (green), with no errors. The problem is when we try to make a call from our side (via call files), we get the pri/E1 error Ext: 1 Cause: Temporary failure (41), class = Network Congestion (2) Our Telecom partner (they checked with Siemens) mentioned that we need to
2006 Dec 18
2
asterisk to asterisk - to zap
Hello that might would be an easy question for someone, but im in doubt Is there any possibility to pass a call from one asterisk to another and then to ZAP channel. For instance I have "A" asterisk with numbering 45670 "B" asterisk with numbering 45680 second asterisk has TE110P card with single PRI port connected to Siemens EWSD. When I originate call from asterisk
2008 Oct 28
3
Dose Profile
Hi Everyone, I have data in a long format e.g. there is one row per patient but each follow-up appointment is included in the row. So, a snippet of the data looks like this: TrialNo Drug Sex Rand Adate1 Date1 Dose1 Time1 Adate2 Date2 Dose2 Time2 B1001029 LTG M 15719 30/04/2003 15825 150 106 29/08/2003 15946 200 227 B1117003 LTG M 15734 30/04/2003 15825 200 91 03/09/2003 15951 250 217
2004 Dec 23
1
Premature DRQ
I have a problem where an Asterisk server is sending a premature DRQ... Not sure why.. Here's the setup - Asterisk using inAccess networks H323 replacement channel driver Connecting to a Lucent iMerge... The call connects fine - I get the out of the box greeting - but after exactly one Minute - the call terminates. I have had this problem on multiple different Asterisk configs... I'm
2011 Oct 10
4
Type of Graph to use
Hi, Please advice on what type of graph can be used to display the following data set. I have the following: Name Class a Class 1 a Class4 b Class2 b Class1 d Class3 d Class5 e Class4 e Class2 So each entry in name can belong to more than one class. I want to represent the data as to see where
2012 Sep 12
3
kernel: dahdi: Master changed to TE2/0/2 --- Is a normal message
I have a server with an asterisk ss7 link connected to a Siemens working well for over a year. A few days ago I started having problems with signaling. I found the following logs in / var / log / messages Sep 12 11:49:25 call3 kernel: [1018427.030959] dahdi: Master changed to TE2/0/2 Sep 12 11:49:25 call3 kernel: [1018427.120740] dahdi: Master changed to TE2/0/1 Sep 12 11:49:26 call3 kernel:
2005 Aug 31
1
Sangoma card problem with EWSD Exchange
Hello All. I'm using sangoma card A-101. tested successful with E10 (ACATEL) Exchange, connection with E1, CAS, (using unicall-0.0.3pre4). my system run success, incoming call and call out are good. when i switch to EWSD (SIEMENS) R-15 . my asterisk faill, cannot connect with EWSD. (E10 and EWSD exchange store in two provinces difference. in Vietnam) this is my logfile of E10
2018 May 15
1
[tablegen] anonymous def not fully instantiated
The following is an extraction from the Operand class hierarchy of Target.td. I am trying to define a parameterized version of AsmOperandClass with a passed-in bit size. // from Target.td class AsmOperandClass { string Name; } class Operand { AsmOperandClass ParserMatchClass; } // A parameterized AsmOperandClass class myAsmOperandClass<int n> : AsmOperandClass { string Name =
2004 Sep 07
2
TE410P in Germany
Is there anyone successfully using the TE410P with a German "PMX-Anschluss"? Please just drop me a note mentioning the carrier you use. We are having problems making the card work, although configuration is correct (Posted this before). Our carrier blames the card for this. We would just need some evidence that it really works. Thanks, Henrik -------------- next part
2005 Nov 06
2
cox models
Hello, i'm a french student of medical oncology and i'm working on breast cancer. I have a variable with the histologic type of tumor wich is between 1 and 5. I use as.factor function to make some variable with level between 1 and 5. When i put it in the cox model i have only the level between 2 and 5. The level 1 doesn't appear. I think i have to change the number of level but i
2005 Jun 06
0
D channel initialization
Hi I have an asterisk box with digium hardware connected to a Siemens EWSD version 15 using a crossed E1 cable. The asterisk is serving as a h323 media gateway. When i start asterisk, the Siemens gives me this alarm: REPORTES GENERADOS EN LA EWSD AES/V15SBOL/BOLCBK1V51327079/013 05-06-06 11:25:38 7773 3062/03728 HF.ARCHIVE-80040
2018 Feb 27
2
scale.default gives an incorrect error message when is.numeric() fails on a sparse row matrix (dgeMatrix)
I am attempting to use the lars package with a sparse input feature matrix, but the following fails: library(Matrix) library(lars) data(diabetes) attach(diabetes) x = as(as.matrix(as.data.frame(x)), 'dgCMatrix') lars(x, y, intercept = FALSE) Error in scale.default(x, FALSE, normx) : > > length of 'scale' must equal the number of columns of 'x' > > More
2012 Jan 26
2
R extracting regression coefficients from multiple regressions using lapply command
Hi, I have a question about running multiple in regressions in R and then storing the coefficients. I have a large dataset with several variables, one of which is a state variable, coded 1-50 for each state. I'd like to run a regression of 28 select variables on the remaining 27 variables of the dataset (there are 55 variables total), and specific for each state, ie run a regression of
2004 Aug 25
0
Asterisks
Take mercy on me - I'm a newbie w/ Asterisks... Here's what I'm trying to do - and please someone let me know if this can be done... We have a commercial VoIP network (we are a communications carrier)... The gatekeeper (Lucent iMerge) supports MGCP/H.323 and allows for calls to be made to the PSTN cloud via GR303 links. I would like to build Asterisks with H323 (or MGCP if need be -
2003 Nov 07
2
Softswitch
Pardon my ignorance, but I was hoping someone could clear up something for me. - For a few POTS lines, digium has a single port card for that, or a T1 card to a channel bank. - For 10 or more lines, digium has a T1 or E1 card for that too based on PRI channels - For 100's to 1000's of lines, I suspect a soft-switch is in order??? A traditional phone company will sell: - POTS lines for
2006 Jul 13
8
can''t convert true into integer
I have a method: ? def reduceProuctInventoryBy(product_id, reduction) ? ? t=Product.find(:first, :conditions =>["id = ?", product_id]) ? ? t.qty=(t.qty-reduction) ? ? t.save ? end and the model: class Product < ActiveRecord::Base ? validates_presence_of :qty, :specialDescription ? validates_numericality_of :qty end but when i run my method, I get this: "can''t