similar to: Fw: Re: Simulating data for sampling (stupid question)

Displaying 20 results from an estimated 1000 matches similar to: "Fw: Re: Simulating data for sampling (stupid question)"

2009 Aug 25
0
Fw: Re: Simulating data (stupid question)
Dear All   I know that you do not have to help me (as this is not a pure R problem) but please do, i am new to R as a CPI compiler, i just need to do a sample to see which sampling method best works in different situations, therefore since this is for practice purposes nobody will finance a real project thats why i need you to help me direct me as to how simulate data (just direct me,not 100%
2011 Oct 07
1
Dynamic HID driver mappings, Tripplite-hid.c
I think I'm going to have the slightly rejigger the tripplite-hid.c driver to 'properly' support all of the data I know about it's outlets. A given UPS may have 'n' output loads. I could have 5, I could have 10, I won't know until I actually ask the UPS. But in order to use the hid to nut struct, I'm actually going to have to modify that struct dynamically, or
2008 Dec 06
1
MGE Evolution and programmable outlets configuration
Hi, I'm a MGE Evolution 650 owner and, after putting in place a basic configuration for controlling my UPS, I'm going to tune a little bit better NUT for my needs. First of all let me describe my little (SOHO) scenario: I have the ISP modem/switch (providing VoIP too, so it's important to keep it running as much as possible), a small low power home server and a much hungrier PC.
2020 Apr 28
2
Tripp-Lite SMART1500LCD: powers off with /etc/killpower...then powers back on...
Hi Everyone, I recently bought a Tripp-Lite SMART1500LCD for my Linux Mint 19.3 machine, connected via a USB cable. I installed Nut 2.7.4 from the Mint package repository via sudo apt update && sudo apt install nut. Everything works great: NUT issues low battery warning when it reaches the set low battery point and then issues shutdown commands...computer shuts down..then the UPS shuts
2007 Aug 23
3
recording current_user
Hi, Another noob here I am afraid! I have a questuin about the current_user method that comes with AAA. I have AAA set up and working fine and if i put <%= self.current_user.login %> into a view it shows the login name as expected on the page. What I cant work out is how to record this into the database when the user completes a form. My app so far only has two models.
2008 May 14
5
RailsConf vs. My MacBook's Battery. ( Power Outlet Availability )
So my Macbook''s battery sucks... and I''m thinking of grabbing a new one, I''m curious how the availability of power outlets have been at RailsConfs. For those who have gone before, was it hard to find an outlet to plug into? Are they mindful of this? I hope so. Thanks in advance. --~--~---------~--~----~------------~-------~--~----~ You received this message because
2015 Jul 15
2
ups does not reboot itself
hello, i have a computer (with debian 8 jessie installed) that i want to plug to an ups (apc smt 750i) to act in netserver mode. i've installed nut packages and configured it and all seems to work ok except that when the server shutdown itself it ups doesn't "reboot" the outlets. i've tested the same config (/etc/nut/*) just changing hostnames in another debian jessie
2006 Jul 13
2
MGE Pulsar Extreme - restart problem
Hello, looking for replacements for some older Powerware equipment I found the MGE Pulsar Extreme 1000C and I'm currently testing one with nut-2.0.3 on a self-brewn i386-linux. Upto now everything seems to work fine - except I can't get the power outlets switching on again after mains returns. As this works with Personal Solution-Pac 2 on W2k I thought that there might be a way to
2008 Jan 20
1
Q about UPS features / NUT support
Hi, I have several Linux machines at home and I'm considering buying a UPS for them. I see that many models are supported by NUT (great!) but since I'm new to the UPS world I have some questions about UPS features and NUT support of them I couldn't find an answer for: 1/ are there UPS models who report/meter power usage through USB? per UPS socket or globally? 2/ are there UPS models
2023 Apr 11
2
Controlling Outlets on UPS
I have a Tripp Lite UPS and I have a configuration switch on one load and the PC plugged into the other load of the UPS is there any way to control the outlets of the UPS using NUT to allow the load the Switch is one to turn on before the PC load? I keep playing around with cloner drivers but they don't seem to be registering in the UPS -------------- next part -------------- An HTML
2006 Jun 27
3
Setting MGE powershare attributes
Hi! We have two MGE Evolution 1100 here, and I want to make use of the powershare outlets to force a particular boot sequence on the machines powered by them. However I'm not sure how to set those variables upon NUT starting, without having to change the init scripts to call "upsrw". Is there some place where I can set them, where they can be read automatically on startup? One of
2015 Jan 21
2
CyberPower BR850ELCD ignores offdelay and turns itself back on while still on battery
Hi there, I just purchased a CyberPower BR850ELCD and while setting NUT up with the install instructions from the homepage was pretty straightforward, and the UPS was detected by the usbhid-ups driver, I'm having problems getting the UPS to work properly. First issue: whatever I set as the offdelay, seems to be ignored and the UPS just cuts the power about 2sec after receiving the
2013 Jun 29
0
upsrw doesn't set variable
On 6/29/2013 at 6:16 PM Kjell Claesson wrote: |l??rdagen den 29 juni 2013 11.28.14 skrev Mike.: |8<------------------snip--------------------- |Hi Mike, |> |> Thanks for the quick reply. |> |> I checked the log file (which, admittedly, I should have done before I |> posted about the problem :) ). |> |> Here's the command and the corresponding log message: |>
2013 Jun 29
1
upsrw doesn't set variable
l?rdagen den 29 juni 2013 15.22.44 skrev Mike.: 8<-------------snip----------------- Sorry for the delay. > Here is the console output of bcmxcp with -DDD specified: > > > [snip] > 13.721204 Auto delay on: 2 > > 13.721243 send_command: (4 bytes) => ab 01 35 1f > 13.821127 send_command: (4 bytes) => ab 01 33 21 > 13.920982
2005 Sep 15
3
OT - where to buy linux HW
Hi List; Anyone know of any good retail or online outlets to but Linux desktops/servers. I would like to acquire another low cost dev box and I refuse to give the M$ chronies any of my money. Thanks for your advice...
2005 Nov 04
3
OPTI-UPS PS (PowerSeries)
Hello, Some time ago i bought 2 OPTI UPS devices, but was really sad to see the page about the OPTI protocol on the nut page. But i don't wanted to give up :) So i sniffed the serial communication using the windows application/driver and found out that these PS (PowerSeries) devices are different than the ES series mentioned on the Nut page. They use some kind of ASCII protocol, with the
2015 Jun 05
2
how do I make my headset work
On 6/5/2015 1:33 PM, Michael Hennebry wrote: > It's a desktop in an old house. > The outlets have ground-fault protection, > but the third prong is ungrounded. > not sure how GFI would function at all without a valid ground, unless the GFI is wired to neutral, which is dangerous on its own. you might get a 3-prong-to-2-prong adapter and plug the PC into that, leaving the ground
2006 Jun 09
1
MGE ellipse 1200 config and documentation
Hi, I have recently purchased MGE ellipse 1200 UPS for my home system. Obviously, the choice of this particular brand was mainly dictated by MGE's long-standing support for Linux and NUT project. The fact that the box was clearly the prettiest looking one on the block did help also ;-). I have had NUT tools installed and configured in no time, as I did it numerous times before -- kudos
2015 Jan 22
0
CyberPower BR850ELCD ignores offdelay and turns itself back on while still on battery
On Jan 21, 2015, at 9:15 AM, Sebastian Hosche <sebastian.hosche at web.de> wrote: > Hi there, > > I just purchased a CyberPower BR850ELCD and while setting NUT up with the install instructions from the homepage was pretty straightforward, and the UPS was detected by the usbhid-ups driver, I'm having problems getting the UPS to work properly. > > First issue: whatever I
2020 Sep 12
1
UPS recommendation for NUT and power-on-delay support
On Fri, 11 Sep 2020, Bartosz wrote: > Could you please recommend me a UPS with 100% support of the ondelay parameter > and NUT compatibility? 850 or 1000 VA I have the EATON 5E850iUSBDIN UPS and it > does not support this parameter so I would like to buy another UPS that for > sure will support it. I have an Eaton Ellipse Eco 1600 bought in 2016 which has a delayed start feature.