Are there any chances that this error can be fixed?
06.05.2025 18:19, Alexey Korobeinikov:> Hi! Thank You!
>
> The UPS behavior are chages with NUT v.2.8.2 but more strange
>
> After this command (if power cord unpluged)
> /usr/local/ups/bin/usbhid-ups -DDDD -a UPS -k
>
> ....
> 0.188173???? [D4] string_to_path: depth = 3
> ?? 0.188187???? [D4] string_to_path: depth = 3
> ?? 0.188199???? [D4] string_to_path: depth = 3
> ?? 0.188211???? [D4] string_to_path: depth = 3
> ?? 0.188246???? [D2] find_nut_info: unknown info type: load.off.delay
> ?? 0.188267???? [D2] find_nut_info: unknown info type: load.off.delay
> ?? 0.188280???? Initiating UPS shutdown
> ?? 0.188290???? [D1] upsdrv_shutdown...
> ?? 0.188298???? [D1] instcmd(shutdown.return, [NULL])
> ?? 0.188316???? [D3] instcmd: using Path
> 'UPS.PowerSummary.DelayBeforeShutdown'
> ?? 0.188332???? [D3] powercom_shutdown_nuf: value = (null), command = 5E00
> ?? 0.224970???? [D3] Report[set]: (3 bytes) => 0f 00 5e
> ?? 0.225003???? [D4] Set report succeeded
> ?? 0.225012???? [D3] instcmd: SUCCEED
>
> The UPS are start double beeping every 2 seconds, but didn't turn off
> himself ( 2 minutes wait )
> UPS are still beeping if power are restored
>
> Status are:
> # upsc ups at localhost
> battery.charge: 100
> battery.charge.low: 70
> battery.charge.warning: 30
> battery.mfr.date: 2014/01/15
> battery.runtime: 800
> battery.type: PbAc
> device.mfr: POWERCOM Co.,LTD
> device.model: HID UPS Battery
> device.serial: 004-0D9F-000
> device.type: ups
> driver.debug: 0
> driver.flag.allow_killpower: 0
> driver.flag.ignorelb: enabled
> driver.name: usbhid-ups
> driver.parameter.offdelay: 30
> driver.parameter.ondelay: 60
> driver.parameter.override.battery.charge.low: 70
> driver.parameter.pollfreq: 30
> driver.parameter.pollinterval: 2
> driver.parameter.port: auto
> driver.parameter.productid: 0004
> driver.parameter.synchronous: auto
> driver.parameter.vendorid: 0d9f
> driver.state: quiet
> driver.version: 2.8.2
> driver.version.data: PowerCOM HID 0.7
> driver.version.internal: 0.53
> driver.version.usb: libusb-1.0.26 (API: 0x1000109)
> input.frequency: 50.0
> input.voltage: 224.0
> input.voltage.nominal: 220
> output.frequency: 50.0
> output.voltage: 224.0
> output.voltage.nominal: 220
> ups.beeper.status: enabled
> ups.date: 2014/01/15
> ups.delay.shutdown: 30
> ups.delay.start: 60
> ups.load: 1
> ups.mfr: POWERCOM Co.,LTD
> ups.model: HID UPS Battery
> ups.productid: 0004
> ups.serial: 004-0D9F-000
> ups.status: OL
> ups.test.result: Done and passed
> ups.timer.shutdown: 269
> ups.timer.start: 0
> ups.vendorid: 0d9f
> root at vTEMPLATE8:/var/log# upsc ups at localhost
> battery.charge: 100
> battery.charge.low: 70
> battery.charge.warning: 30
> battery.mfr.date: 2014/01/15
> battery.runtime: 800
> battery.type: PbAc
> device.mfr: POWERCOM Co.,LTD
> device.model: HID UPS Battery
> device.serial: 004-0D9F-000
> device.type: ups
> driver.debug: 0
> driver.flag.allow_killpower: 0
> driver.flag.ignorelb: enabled
> driver.name: usbhid-ups
> driver.parameter.offdelay: 30
> driver.parameter.ondelay: 60
> driver.parameter.override.battery.charge.low: 70
> driver.parameter.pollfreq: 30
> driver.parameter.pollinterval: 2
> driver.parameter.port: auto
> driver.parameter.productid: 0004
> driver.parameter.synchronous: auto
> driver.parameter.vendorid: 0d9f
> driver.state: quiet
> driver.version: 2.8.2
> driver.version.data: PowerCOM HID 0.7
> driver.version.internal: 0.53
> driver.version.usb: libusb-1.0.26 (API: 0x1000109)
> input.frequency: 50.0
> input.voltage: 224.0
> input.voltage.nominal: 220
> output.frequency: 50.0
> output.voltage: 224.0
> output.voltage.nominal: 220
> ups.beeper.status: enabled
> ups.date: 2014/01/15
> ups.delay.shutdown: 30
> ups.delay.start: 60
> ups.load: 1
> ups.mfr: POWERCOM Co.,LTD
> ups.model: HID UPS Battery
> ups.productid: 0004
> ups.serial: 004-0D9F-000
> ups.status: OL
> ups.test.result: Done and passed
> ups.timer.shutdown: 89
> ups.timer.start: 0
> ups.vendorid: 0d9f
> root at vTEMPLATE8:/var/log# upsc ups at localhost
> battery.charge: 100
> battery.charge.low: 70
> battery.charge.warning: 30
> battery.mfr.date: 2014/01/15
> battery.runtime: 800
> battery.type: PbAc
> device.mfr: POWERCOM Co.,LTD
> device.model: HID UPS Battery
> device.serial: 004-0D9F-000
> device.type: ups
> driver.debug: 0
> driver.flag.allow_killpower: 0
> driver.flag.ignorelb: enabled
> driver.name: usbhid-ups
> driver.parameter.offdelay: 30
> driver.parameter.ondelay: 60
> driver.parameter.override.battery.charge.low: 70
> driver.parameter.pollfreq: 30
> driver.parameter.pollinterval: 2
> driver.parameter.port: auto
> driver.parameter.productid: 0004
> driver.parameter.synchronous: auto
> driver.parameter.vendorid: 0d9f
> driver.state: quiet
> driver.version: 2.8.2
> driver.version.data: PowerCOM HID 0.7
> driver.version.internal: 0.53
> driver.version.usb: libusb-1.0.26 (API: 0x1000109)
> input.frequency: 50.0
> input.voltage: 226.0
> input.voltage.nominal: 220
> output.frequency: 50.0
> output.voltage: 226.0
> output.voltage.nominal: 220
> ups.beeper.status: enabled
> ups.date: 2014/01/15
> ups.delay.shutdown: 30
> ups.delay.start: 60
> ups.load: 1
> ups.mfr: POWERCOM Co.,LTD
> ups.model: HID UPS Battery
> ups.productid: 0004
> ups.serial: 004-0D9F-000
> ups.status: OL
> ups.test.result: Done and passed
> ups.timer.shutdown: 3148
> ups.timer.start: 0
> ups.vendorid: 0d9f
>
> And strange with timer parametr that are changes cycling:
> ups.timer.shutdown: 3570
> ups.timer.shutdown: 2430
> ups.timer.shutdown: 1710
> ...
> ups.timer.shutdown: 870
> ups.timer.shutdown: 3629
> ups.timer.shutdown: 2729
> ups.timer.shutdown: 1829
> ...
> ups.timer.shutdown: 89
> ups.timer.shutdown: 3148
> ...
>
> the ups.conf are:
> [UPS]
> ??? driver = usbhid-ups
> ??? vendorid = 0d9f
> ??? productid = 0004
> #??? powercom_sdcmd_byte_order_fallback
> ??? port = auto
> #??? pollonly = enabled
> ??? pollinterval = 2
> ??? pollfreq = 30
> ??? offdelay = 30
> ??? ondelay = 60
> ??? allow_killpower
> ??? ignorelb
> ??? override.battery.charge.low = 70
> #??? override.battery.runtime.low = 600
>
> 06.05.2025 01:49, Jim Klimov:
>> At least the "shutdown.return requires a parameter" part
*may* be a
>> regression of the new "sdcommands" change in v2.8.3,though I
don't
>> think older code passed any. Maybe something got lost in mass-edit
>> changes though.
>>
>> Can you please double-check with 2.8.2 if its older approach to UPS
>> shutdown behaved better?
>>
>> Jim Klimov
>>
>> On Tue, May 6, 2025, 00:41 Alexey Korobeinikov <alexey at
fseafood.com>
>> wrote:
>>
>> Hi, my UPS Model Powercom BNT400AP ( made 2017.12 ) on Linux Devuan
>> Daedalus and NUT v2.8.3 (install from source tarball with
"configure
>> --with-usb --with-user=nut --with-group=nut --with-libusb=1.0
>> --with-statepath=/run/nut --with-pidpath=/run/nut" options)
didn't
>> shutdown itself after OS is shuting down by signal of UPS battary
>> is low.
>>
>> ...
>>
>> ???0.184242 ????Initiating UPS [UPS] shutdown
>> ???0.184257 ????[D1] loop_shutdown_commands: call
>> do_loop_shutdown_commands() with driver-default sdcommands
>> ???0.184267 ????[D1] Starting
>> do_loop_shutdown_commands(shudown.default), call depth 1...
>> ???0.184280 ????[D1] upsdrv_shutdown...
>> ???0.184289 ????[D1] Starting
>>
do_loop_shutdown_commands(shutdown.return,shutdown.reboot,load.off.delay,shutdown.stayoff),
>>
>> call depth 2...
>> ???0.184299 ????[D1] instcmd(shutdown.return, [NULL])
>> ???0.184313 ????[D3] instcmd: using Path
>> 'UPS.PowerSummary.DelayBeforehutdown'
>> ???0.184321 ????[D2] instcmd: shutdown.return requires an explicit
>> parameter
>>
>> ???0.184331 ????[D1] instcmd(shutdown.reboot, [NULL])
>> ???0.184348 ????[D2] find_nut_info: unknown info type:
>> shutdown.reboot
>> ???0.184358 ????[D3] instcmd: cmdname 'shutdown.reboot' not
found;
>> checking for alternatives
>> ???0.184371 ????[D2] instcmd: info element unavailable
>> shutdown.reboot
>>
>> ???0.184387 ????[D1] instcmd(load.off.delay, [NULL])
>> ???0.184398 ????[D2] find_nut_info: unknown info type:
load.off.delay
>> ???0.184407 ????[D3] instcmd: cmdname 'load.off.delay' not
found;
>> checking for alternatives
>> ???0.184418 ????[D2] instcmd: info element unavailable
load.off.delay
>>
>> ???0.184428 ????[D1] instcmd(shutdown.stayoff, [NULL])
>> ???0.184438 ????[D3] instcmd: using Path
>> 'UPS.PowerSummary.DelayBeforehutdown'
>> ???0.184449 ????[D2] instcmd: shutdown.stayoff requires an explicit
>> parameter
>>
>> ???0.184462 ????[D1] Ending
>>
do_loop_shutdown_commands(shutdown.return,shutdown.reboot,load.off.delay,shutdown.stayoff),
>>
>> call
>> depth 2: return-code 2
>> ???0.184471 ????Shutdown failed!
>> ???0.184483 ????[D1] set_exit_flag: raising exit flag due to
>> signal -1
>> ???0.184493 ????[D1] do_loop_shutdown_commands(): command
>> 'shutdown.default' was handled successfully
>> ???0.184502 ????[D1] Ending
>> do_loop_shutdown_commands(shutdown.default),
>> call depth 1: return-code 0
>> ???0.184512 ????UPS [UPS]: shutdown request was successful with
>> 'shutdown.default'
>> ???0.184523 ????[D1] set_exit_flag: raising exit flag due to
>> programmatic abort: EXIT_FAILURE
>> ???0.184540 ????[D1] upsdrv_cleanup...
>> ???0.184899 ????[D1] upsnotify: failed to notify about state
>> NOTIFY_STATE_STOPPING: no notification tech defined, will not
>> spam more about it
>> ???0.184936 ????[D1] On systems without service units, consider
>> `export
>> NUT_QUIET_INIT_UPSNOTIFY=true`
>>
>> I try to use "powercom_sdcmd_byte_order_fallback" option,
with
>> same effect.
>>
>> Wat's wrong with my UPS/NUT ?
>> Thank You!
>>
>> --
>> Oleksii Korobeinikov
>>
>>
>>
>>
>> _______________________________________________
>> Nut-upsuser mailing list
>> Nut-upsuser at alioth-lists.debian.net
>>
https://alioth-lists.debian.net/cgi-bin/mailman/listinfo/nut-upsuser
>>
>
> --
> ? ???????
> ???????????? ???????
> ????????? ?????????????
>
> ??? "??????? ?????"
> ???. ?????????? 152, ??? ?????? ???????
> ???????? ???????, 07442
> ?.+38 044 495-88-00
> ??.6101
> ?.+38 067 994-40-48
>
> _______________________________________________
> Nut-upsuser mailing list
> Nut-upsuser at alioth-lists.debian.net
> https://alioth-lists.debian.net/cgi-bin/mailman/listinfo/nut-upsuser
--
? ???????
???????????? ???????
????????? ?????????????
??? "??????? ?????"
???. ?????????? 152, ??? ?????? ???????
???????? ???????, 07442
?.+38 044 495-88-00
??.6101
?.+38 067 994-40-48
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
<http://alioth-lists.debian.net/pipermail/nut-upsuser/attachments/20250512/95c8b450/attachment-0001.htm>