S K
2022-Nov-17 02:33 UTC
[Nut-upsuser] [EXTERNAL] CP1350PFCLCD - Reporting wrong output voltage as 136 VAC
Hey?wolfy,How do I run the debug mode on command line? FYI, I have a raspberry PI "monitoring" the cyber power UPS and my cyper power UPS (identical ones) are physically connected to Synology NAS and Openmediavault On Wednesday, November 16, 2022 at 08:00:24 PM EST, Manuel Wolfshant <manuel.wolfshant at gmail.com> wrote: On November 17, 2022 1:09:34 AM GMT+02:00, S K via Nut-upsuser <nut-upsuser at alioth-lists.debian.net> wrote:> The display shows 119VCan you please run the driver in debug mode (-DDD), collect 20-30 secs worth of logs and then let us see them (I guess a zip sent here should do ) ? We have to see what actual values? is the UPS sending in order to differentiate between UPS reporting incorrect values and nut misinterpreting the values it receives. wolfy -->? On Wednesday, November 16, 2022 at 05:55:00 PM EST, Zomaya, David <davidzomaya at eaton.com> wrote:? > > >? Hey there I have NUT version 2.7.4 and the Cyber Power CP1350PFCLCD reports as 136 volts as output! Interesting I have two of the same model and they report the SAME output 136 VA > >Does the LCD report an OUTPUT voltage value other than 136? > CP1350PFCLCD is a line interactive UPS so maybe it is boosting input. > >Thanks, >David Zomaya >-------------- next part -------------- An HTML attachment was scrubbed... URL: <http://alioth-lists.debian.net/pipermail/nut-upsuser/attachments/20221117/e34046cc/attachment-0001.htm>
S K
2022-Nov-17 15:49 UTC
[Nut-upsuser] [EXTERNAL] CP1350PFCLCD - Reporting wrong output voltage as 136 VAC
Enclosed logs as zip file On Wednesday, November 16, 2022 at 09:35:27 PM EST, S K via Nut-upsuser <nut-upsuser at alioth-lists.debian.net> wrote: Hey?wolfy,How do I run the debug mode on command line? FYI, I have a raspberry PI "monitoring" the cyber power UPS and my cyper power UPS (identical ones) are physically connected to Synology NAS and Openmediavault On Wednesday, November 16, 2022 at 08:00:24 PM EST, Manuel Wolfshant <manuel.wolfshant at gmail.com> wrote: On November 17, 2022 1:09:34 AM GMT+02:00, S K via Nut-upsuser <nut-upsuser at alioth-lists.debian.net> wrote:> The display shows 119VCan you please run the driver in debug mode (-DDD), collect 20-30 secs worth of logs and then let us see them (I guess a zip sent here should do ) ? We have to see what actual values? is the UPS sending in order to differentiate between UPS reporting incorrect values and nut misinterpreting the values it receives. wolfy -->? On Wednesday, November 16, 2022 at 05:55:00 PM EST, Zomaya, David <davidzomaya at eaton.com> wrote:? > > >? Hey there I have NUT version 2.7.4 and the Cyber Power CP1350PFCLCD reports as 136 volts as output! Interesting I have two of the same model and they report the SAME output 136 VA > >Does the LCD report an OUTPUT voltage value other than 136? > CP1350PFCLCD is a line interactive UPS so maybe it is boosting input. > >Thanks, >David Zomaya >_______________________________________________ Nut-upsuser mailing list Nut-upsuser at alioth-lists.debian.net https://alioth-lists.debian.net/cgi-bin/mailman/listinfo/nut-upsuser -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://alioth-lists.debian.net/pipermail/nut-upsuser/attachments/20221117/8f2246d8/attachment-0001.htm> -------------- next part -------------- A non-text attachment was scrubbed... Name: ups.zip Type: application/x-zip-compressed Size: 5189 bytes Desc: not available URL: <http://alioth-lists.debian.net/pipermail/nut-upsuser/attachments/20221117/8f2246d8/attachment-0001.bin>