2004 Jun 17
4
Problems with PRI with T410 messages
Hi all, I have a box running asterisk with T410 connected to a Nortel DMS 100 switch and another box running SER with grandstream phones on it So if there is a call from the pstn it goes from the Nortel to the asterisk and then to the SER box and finally to the phones.if the phone is busy or the number is invalid the * box will first send an ALERT message to the Nortel and say the call is going on
2004 Jun 14
1
TE410P in Austria
hi all, i've now installed a TE410P (Quad T1/E1 Primary Card - Digium) and connected it to a primary line. My telco (eTel) only told me that they are using hdb3 and crc4. So i still don't know which coding i have to use (cas or ccs) - and what timing options i have to use. Have someone already get a card like this up in Austria with a line from eTel or from the telekom Austria ? Another
2003 Sep 25
3
configuring TE410P for four E1 PRI lines
hi, I'm trying to configure my newly acquired TE410P card to work as 4 E1 spans. This is supposed to be a drop-in replacement to the earlier E100P card. However, on loading the zaptel module it gets configured as T1 spans basically doing a 'cat' on /proc/zaptel/1 thru 4, it shows 24 channels per span. After this ztcfg fails saying 'ZT_CHANCONFIG failed for channel 97'.
2003 Dec 27
1
Outgoing call with bad/choppy sound
Hi all. I have this configuration: Telco <-----(E1)----->TE410P//Dual Xeon Server 2.4Ghz<-----(Ethernet)----->Switch<----->GS//BT The Server is running RedHat Linux 8.0 with kernel 2.4.18-14-smp and we are having the following 2 issues: 1.- When making calls from the GrandStream to the PSTN the audio is choopy, plus theres is a pulsing sound, but when the GS
2004 Jul 02
1
TE410P PINS
hi all, i am getting crazy with my TE410P - it won't work now we already think that the only thing which can be wrong is the cable. At our telecom endpoint we have 1-2 tx, 4-5 rx So - which cable do i need to get it working Already tried a cross over cable 1-2 -> 4-5 / 4-5 -> 1-2 (with this cable nothing works -> red alarm on both ends) Also a normal cable 1-2 -> 1-2 / 4-5 ->
2005 Aug 23
1
Asterisk 1.0.9: TE411P replacement for TE410P 1stgen causes crashes
Hi all, I replaced a TE410P Rev C 1st Generation Firmware with a TE411P without any cfg changes (zaptel/zapata). As a result Asterisk crashes on outbound from PRI4 going to PRI1 calls: Aug 23 18:22:00 WARNING[4693]: chan_zap.c:7545 zt_pri_error: PRI: !! Got a UA, but i'm in state 1 Aug 23 18:22:00 WARNING[4693]: chan_zap.c:7545 zt_pri_error: PRI: !! Got a UA, but i'm in state 1
2004 Sep 06
0
Wildcard TE410P still making trouble
We are still having problems getting a Wildcard to work with a German E1 (PMX) interface. When starting asterisk it shows all B-channels starting up successfully (although our carrier told us only the first B-channel starts, if any at all). Incoming calls are not being signaled at all. (They seem to be intercepted by the carrier's switch, as no B-channel is up) Outgoing calls sometimes work,
2005 Jan 04
1
HDLC Bad FCS (8) HDLC Abort on TE410P
Dear All, we have installed a TE410P card on a Dell Poweredge 1750 running a slackware 10 with 2.4.26 Kernel. Then we have made two loops on the card and we have configurated all the 120 channels. Our goals was to perform some stess tests even if in this scenario we used the same box as generator and target. The stress test comprised to generate up to 60 calls at the same time by placing a file
2004 Nov 20
1
TE410P PRI problems
Hi all! I'm trying to replace our old Siemens PBX with Asterisk. I've installed a TE410P card on a Linux box (Fedora Core 2 - 2.6.x kernel). I had no problem with compiling and installing modules and according to dmesg/zttool everything is ok. However, even though I've configured extensions.conf to play a greeting message when dialed, I can't get it to work. When I type
2007 May 03
2
Wildcard TE410P problem
Hello all, I'm using Wildcard TE410P card. Here is a zaptel.cfg loadzone=se defaultzone=se span=1,1,0,ccs,hdb3,crc4 bchan=1-15 dchan=16 bchan=17-31 span=2,0,0,ccs,hdb3,crc4 bchan=32-46 dchan=47 bchan=48-62 span=3,0,0,ccs,hdb3,crc4 bchan=63-77 dchan=78 bchan=79-93 span=4,0,0,ccs,hdb3,crc4 bchan=94-108 dchan=109 bchan=110-124 # ztcfg -vvv Zaptel Configuration ====================== SPAN 1:
2005 Sep 30
1
TE410P not working
I'm trying to install a TE410P this is what happens with compiled zaptel 1.0.9, 1.2-beta and 1.0.9 from http://updates.xorcom.com/iso/ this is my zaptel.conf (checked with the provider the values): span=1,1,0,ccs,hdb3,crc4 bchan=1-15,17-31 dchan=16 loadzone=it defaultzone=it then I modprobe wct4xxp debug=1 t1e1override=15 and the kernel says : Sep 30 16:12:40 localhost kernel: Zapata
2005 Jul 21
1
SOLVED: TE410P card in an HP-Compaq DL380 G4 server
Hi to all out there using HP DL380 G4 servers, i found a way to get the Digium TE410P with older firmware running on a HP-Compaq DL380 G4 Server! Here's the step-by-step description: 1. download the latest BIOS (in my case it was 4.04 from date: 06/02/2005) for the HP-Compaq DL380 G4 using the "Systems ROMPaq Firmware Upgrade Diskette for HP ProLiant DL480 G4 (P51) Servers" Link:
2004 Apr 01
2
PRI integration with Marconi switch
Hello- Has anyone had experience connecting to a Marconi switch (in the UK) using E1-PRI connections (TE410P)? In a new installation, my customer is getting yellow alarms on every channel about every 30 seconds. These alarms clear themselves immediately and then re-occur in another 30 seconds, ad infinitum. I used the same configuration that I've used successfully in the past while talking
2006 Apr 22
4
Pinouts for T1/E1 crossover cable WAS "RE: what cable to connect a legacy PBX to a TE410P ?"
Can't anyone stop self-promotion and tell the poor guy what he needs. A T1/E1 X-over cable using an RJ-45 (8-cond.) is pinned out as follows: 1 - 4 2 - 5 3 - NU 4 - 1 5 - 2 6 - NU 7 - NU 8 - NU NU = Not Used I have not in my experience seen any problems with using a Good Quality Cat5 vs. Cat 3 (telco standard) cable for X-connects. YMMV, but you should be fine. As far as the shielding
2005 Jun 05
2
te410p not working after cvs-head update
I have a TE410P running on CentOS 4 which (fortunately) is my test system. This card has been working flawlessly for the past few weeks. Today I did a cvs update to the latest head files, and the card is now not working. When I try a zaptel start, a series of messages appears on the console: Found TE410p at base address fdff0000, remapped to f8a34000 TE410P version c01a010b, burst ON, slip
2005 Jan 06
1
TE410P problem (Looping UP Span 1...)
Hi list, We have been trying to configure a Quad Span T1 card in a system running RH9. We have followed the instructions in the Wiki and searched the mailing lists, but so far havent got any success. Cable is connected to the first span, and module is loaded. Without loading the module the LED glows in red colour, but the moment we load module, it goes off. (No red or green) . We ran zttool
2004 Mar 21
5
PRI issues with TE410P
Hi, I am having some problems mentioned below, the box is in production live environment with traffic around 30 - 100 calls. I am running T/E410P in a Dual P4 xeon with HT disabled. I am using zaptel 0.9.0 and asterisk stable 1 release. There is no gui, just mysql, perl (small script) and asterisk. System runs very smoothly if the calls are around 40-50 and comes one by one , however sometimes
2003 Sep 01
1
TE410P - one way audio, after "rpm -qa" on RedHat 9
TE410P - one way audio, after "rpm -qa" on RedHat 9 After much trouble, I can consistently reproduce this error. Anyone have any idea why all Zap channels on my TE410P would develop one way audio after "rpm -qa" has been run while asterisk is running? If I reboot, run "rpm -qa" first then load asterisk and modules all is OK when "rpm -qa" runs the second
2006 Oct 13
1
Digium TE410P LED problem
Has anyone else experienced a problem with the LED for span 1 on a TE410P or TE405P? I had a TE410P on which the span 1 LED would not light red, but once the span was connected, it did correctly light green. I RMAed the board to our UK distrbutor and received a replacement. However, the replacement board displayed the same problem! Wondering if it was related to the computer I was putting it
2004 Jul 18
1
TE405P
I'm installing TE405P card. This is my zaptel.conf. -------------------------------------- span=1,0,0,ccs,hdb3,crc4 span=2,1,0,ccs,hdb3,crc4 span=3,0,0,ccs,hdb3,crc4 span=4,0,0,ccs,hdb3,crc4 loadzone = us defaultzone= us -------------------------------------- When i modprobe wct4xxp, -------------------------------------- PCI: Found IRQ 11 for device 02:0b.0 PCI: Sharing IRQ 11 with