Displaying 4 results from an estimated 4 matches for "hu_find_valinfo".
2013 Feb 08
0
Very long delay for shutdown.restart on usbhid-ups powercom
...turn", it seems delay value is badly
converted:
$> upscmd STD80S shutdown.return 30
Driver debug logs show the command as correctly processed, but with
uncorrect parameters:
55.348163 instcmd(shutdown.return, 30)
55.348205 powercom_shutdown_nuf: value = 30, command = 5E00
55.348218 hu_find_valinfo: found 24064 (value: 30)
55.348229 Unit = 00000000, UnitExp = 0
55.348239 Exponent = 0
55.348249 PhyMax = 0, PhyMin = 0, LogMax = 65535, LogMin = 0
55.348920 Report[set]: (3 bytes) => 0f 00 5e
55.348945 Set report succeeded
55.348956 instcmd: SUCCEED
Value 30 is converted to 24064,...
2016 May 28
0
Powercom INF-800 support
...shutdown.return it. Maybe protocol is not fully
> compatible?
>
> 0.145757 Initiating UPS shutdown
> 0.145760 upsdrv_shutdown...
> 0.145763 instcmd(shutdown.return, [NULL])
> 0.145767 powercom_shutdown_nuf: value = (null), command = 5400
> 0.145770 hu_find_valinfo: found 21504 (value: (null))
> 0.145773 Unit = 00000000, UnitExp = 0
> 0.145775 Exponent = 0
> 0.145778 PhyMax = 0, PhyMin = 0, LogMax = 65535, LogMin = 0
> 0.155952 Report[set]: (3 bytes) => 0f 00 54
> 0.155981 Set report succeeded
> 0.155986...
2016 May 28
1
Powercom INF-800 support
...e protocol is not
> fully compatible?
>
> 0.145757 Initiating UPS shutdown
> 0.145760 upsdrv_shutdown...
> 0.145763 instcmd(shutdown.return, [NULL])
> 0.145767 powercom_shutdown_nuf: value = (null), command = 5400
> 0.145770 hu_find_valinfo: found 21504 (value: (null))
> 0.145773 Unit = 00000000, UnitExp = 0
> 0.145775 Exponent = 0
> 0.145778 PhyMax = 0, PhyMin = 0, LogMax = 65535, LogMin = 0
> 0.155952 Report[set]: (3 bytes) => 0f 00 54
> 0.155981 Set report succeede...
2016 May 28
2
Powercom INF-800 support
...st
However I was unable to shutdown.return it. Maybe protocol is not fully
compatible?
0.145757 Initiating UPS shutdown
0.145760 upsdrv_shutdown...
0.145763 instcmd(shutdown.return, [NULL])
0.145767 powercom_shutdown_nuf: value = (null), command = 5400
0.145770 hu_find_valinfo: found 21504 (value: (null))
0.145773 Unit = 00000000, UnitExp = 0
0.145775 Exponent = 0
0.145778 PhyMax = 0, PhyMin = 0, LogMax = 65535, LogMin = 0
0.155952 Report[set]: (3 bytes) => 0f 00 54
0.155981 Set report succeeded
0.155986 instcmd: SUCCEED
Ever...