2006 Oct 23
2
T.38 faxing with spandsp and Grandstream HT.486
Hello ! I 'm trying T.38 faxig with spandsp using rxfax/txfax as fax terminal. As another endpoint I 'm using Grandstream HT 486 ATA and a fax machine. Has anybody success with the HT486 as T.38 terminal ? ATA as originator: I managed only onetimes a successfull T.38 fax session. The other times the HT486 did not initiate a re-invite with T.38 parameters. Or shall the Terminator inititate a re-invite ? txfax as originator: T.38 fax exchange takes place but the transmission is n...
2004 Oct 01
2
HT 486
Does anyone know if the HandyTone 486 has the option to turn the two ethernet ports into either a switch/hub, or does it have to do NAT ? Thank you, Steve Maroney
2005 May 28
1
Fax and SIP Device
A DID number was dedicated to receive fax, but i have the problem when getting fax call, which call will become a normal phone call and no fax was printed. When fax is detected, the fax extension is executed and dial the extension of the HT486 device (firmware 1.0.5.22). Somehow sending fax out working well. In the mailing lists, i notice some are using HT286 and it work. Could someone share theirs experience and give some help? E1 PSTN ----------> Asterisk (TE100P) --------> HT486 ----> Fax machine zapata.co...
2006 Feb 22
6
Best ATA for general residential deployment??
I read the thread about what IP phone is best for business deployment with great interest. Our need is slightly different however. We are deploying VoiP as a value-add with our high speed internet service and are having trouble finding the right SIP analog terminal adapter. In order to support people's existing phones and wiring we need to use an ATA. 1) The first priority is we want
2005 Oct 17
2
Bizarre Echo Problem
Before I relate the actual problem, some context. Callcentre environment, a few users testing a new digital dialer... 1. Agents are using Grandstream ATA HT486 and a small analogue dialpad with a headset. 2. SIP connection to Asterisk-1.2b1 3. IAX2 connection to ITSP provider. The call is initially set up in the following way. 1. Agent calls into a meetme conference room and subseqently stays in the conference room working offhook. 2. Dialler originates...
2004 Sep 22
2
Grandstream bin cfg.txt generator
Hi, I needed to create config files for downloading to Grandstream devices and made a little script for it. It seems to work fine for the HT486. The script needs a config file (cfg.in) which is in this format: P2 = blah P10 = hrm ...etc... The configfile may contain comments (starting with '#') and empty lines. Mind that the 'gnkey=0b82' shouldn't be in the configfile, as it's already appended by the script. Ho...
2004 Aug 31
2
multiple lines with SIP like MGCP?
We have a Dlink DVG-1120M and were surprised that it was able to handle 2 simultaneous conversations to 2 seperate phones using only 1 MAC address and 1 IP address. So we asked ourselves..why can't other 1 MAC/1IP devices do this as well? I have a Grandstream 486 that has 1IP and 1MAC. But I don't see anywhere in sip.conf to add a second line to a device. Is this possible? Can this only
2005 May 08
3
Grandstream firmware 1.0.6.2
Grandstream owners, I just noticed that there is a new firmware release, for those that are interested: http://www.grandstream.com/BETATEST/ Doug
2006 Feb 07
1
ATA's and faxing
Hi All Is there any special configuration needed to send and receive faxes on an ATA device? I am using G711.a with a Grandstream Handytone 486. I can send faxes from a fax machine on the ATA, but receiving doesn't work. I get the fax signal, but it just doesn't continue. The LAN is used purely for VoIP traffic. Garth
2006 Feb 13
1
iLBC issue: An ilbc frame that isn't a multiple of 50 bytes long from RTP (38)
...implementing iLBC on some of the ATAs we have floating around clients' homes, but I'm coming against this error message with most of them: codec_ilbc.c: Huh? An ilbc frame that isn't a multiple of 50 bytes long from RTP (38)? The ATAs in question are various Grandstream models - the HT486 being the predominant one. Looking at the list archives, it's been an issue for others in the past, but there doesn't appear to have been a satisfactory solution I could find. I understand it's an issue with payload types, so as recommended in the posts I've read, DTMF is set to pay...
2004 Jul 22
0
Application Hangup not hanging up, possible dialplan cockup?
...3f To: <sip:13015555555@serverIP>;tag=as12bc5f06 Contact: <sip:3015845559@clientIP> Proxy-Authorization: DIGEST username="3015845559", realm="asterisk", algorithm=MD5, uri="sip:130155$Call-ID: a4a6525be5bd113a@192.168.0.24 CSeq: 33097 ACK User-Agent: Grandstream HT486 1.0.4.59 Max-Forwards: 70 Allow: INVITE,ACK,CANCEL,BYE,NOTIFY,REFER,OPTIONS,INFO,SUBSCRIBE Content-Length: 0 12 headers, 0 lines -- Executing Playback("SIP/3015845559-bf64", "im-sorry") in new stack -- Playing 'im-sorry' (language 'en') -- Executing...
2004 Dec 12
2
[OT] Small SIP phones?
Hi. Does anyone know of any small SIP phones (and preferably have some experience of using them and happy to recommend them)? By 'small' I mean a single-piece phone, with dial buttons in the handset, so that it can be carried around easily in a laptop bag. Something like http://maplin.co.uk/images/Full/35493i0.jpg (which is unfortunately just a standard analogue telephone).